Lager: Nach dem Einlagern wurde EAN nicht richtig gecleart.
authorSven Schöling <s.schoeling@linet-services.de>
Mon, 19 Jul 2010 08:27:35 +0000 (10:27 +0200)
committerSven Schöling <s.schoeling@linet-services.de>
Mon, 19 Jul 2010 08:27:35 +0000 (10:27 +0200)
Fix für Bug 1455.

bin/mozilla/wh.pl

index 3b732bc..89975cc 100644 (file)
@@ -503,7 +503,7 @@ sub transfer_stock {
 
   WH->transfer($transfer);
 
-  delete @{$form}{qw(parts_id partnumber description qty unit chargenumber bestbefore comment)};
+  delete @{$form}{qw(parts_id partnumber description qty unit chargenumber bestbefore comment ean)};
 
   $form->{saved_message} = $locale->text('The parts have been stocked.');
   $form->{trans_type}    = 'stock';