posaune
authorMichael J.M. Wagner <michael@wagnertech.de>
Mon, 11 Dec 2023 20:54:19 +0000 (21:54 +0100)
committerMichael J.M. Wagner <michael@wagnertech.de>
Mon, 11 Dec 2023 20:54:19 +0000 (21:54 +0100)
Griesstatt/fhem.cfg

index 65d7d65..ea9332c 100644 (file)
@@ -3,11 +3,10 @@ attr global autoload_undefined_devices 1
 attr global autosave 0
 attr global logfile ./log/fhem-%Y-%m.log
 attr global modpath .
-attr global motd SecurityCheck:\
-  telnetPort is not password protected\
+attr global motd Messages collected while initializing FHEM:\
+configfile: telnetPort already defined, delete it first\
 \
-Protect this FHEM installation by configuring the allowed device allowed_WEB\
-You can disable this message with attr global motd none
+Autosave deactivated
 attr global statefile ./log/fhem.save
 attr global verbose 3
 
@@ -33,13 +32,6 @@ setuuid eventTypes 5d07a041-f33f-d703-e43c-930c656ddea2cd5a
 # Disable this to avoid looking for new USB devices on startup
 define initialUsbCheck notify global:INITIALIZED usb create
 setuuid initialUsbCheck 5d07a041-f33f-d703-f259-0751a20adc04fee2
-define RPi GPIO4 BUSMASTER
-setuuid RPi 5d07a041-f33f-d703-88e1-d3df5301a9a2810c
-define KellerTemp GPIO4 28-00000a54cd2a
-setuuid KellerTemp 5d07a041-f33f-d703-1079-da21805d0c596460
-attr KellerTemp model DS18B20
-attr KellerTemp room Temperaturen
-attr KellerTemp tempOffset -1.0
 define KNX TUL tul:/dev/ttyACM0@57600 1.1.255
 setuuid KNX 5d07a18b-f33f-d703-97fe-8c0cc64740b9ed0b
 define KNX_0000003 KNX 0/0/3:dpt9.001
@@ -108,6 +100,7 @@ setuuid KNX_0000002_notify_1 5d07f609-f33f-d703-d7ab-35661dde8ebe4b02
 define KNX_0003188 KNX 0/3/188:MODEL_NOT_DEFINED
 setuuid KNX_0003188 5d08b7d7-f33f-d703-97e6-db5c03954880ba87
 attr KNX_0003188 IODev KNX
+attr KNX_0003188 disable 1
 attr KNX_0003188 room KNX
 define FileLog_KNX_0003188 FileLog ./log/KNX_0003188-%Y.log KNX_0003188
 setuuid FileLog_KNX_0003188 5d08b7d7-f33f-d703-edc8-4501566baeec6d7c
@@ -115,3 +108,56 @@ attr FileLog_KNX_0003188 logtype text
 attr FileLog_KNX_0003188 room KNX
 define telnetPort telnet 7072 global
 setuuid telnetPort 5df68b4a-f33f-d703-4f7b-cb3742bcd8220943
+define KNX_0101001 KNX 1/1/1:MODEL_NOT_DEFINED
+setuuid KNX_0101001 5df750fa-f33f-d703-57ed-626773e098172585
+attr KNX_0101001 IODev KNX
+attr KNX_0101001 disable 1
+attr KNX_0101001 room KNX
+define KNX_0101251 KNX 1/1/251:MODEL_NOT_DEFINED
+setuuid KNX_0101251 5df750fb-f33f-d703-275b-08f7293994ac2a5b
+attr KNX_0101251 IODev KNX
+attr KNX_0101251 disable 1
+attr KNX_0101251 room KNX
+define FileLog_KNX_0101251 FileLog ./log/KNX_0101251-%Y.log KNX_0101251
+setuuid FileLog_KNX_0101251 5df7510a-f33f-d703-300a-b5d2b3feac1ff427
+attr FileLog_KNX_0101251 logtype text
+attr FileLog_KNX_0101251 room KNX
+define FileLog_KNX_0101001 FileLog ./log/KNX_0101001-%Y.log KNX_0101001
+setuuid FileLog_KNX_0101001 5df7510a-f33f-d703-339d-f373f346f95fa05f
+attr FileLog_KNX_0101001 logtype text
+attr FileLog_KNX_0101001 room KNX
+define KNX_0002000 KNX 0/2/0:MODEL_NOT_DEFINED
+setuuid KNX_0002000 5e0914c6-f33f-d703-414e-1b22ae4fea94f8f0
+attr KNX_0002000 IODev KNX
+attr KNX_0002000 disable 1
+attr KNX_0002000 room KNX
+define FileLog_KNX_0002000 FileLog ./log/KNX_0002000-%Y.log KNX_0002000
+setuuid FileLog_KNX_0002000 5e0914c6-f33f-d703-1198-69f7ab329b56fd83
+attr FileLog_KNX_0002000 logtype text
+attr FileLog_KNX_0002000 room KNX
+
+# include from xfhem package
+include wagnertech.cfg
+define watchdog at +*00:10:00 "/usr/share/sysal/bin/triggerWatchdog_REST http://wagnertech.de/sysal/rest rwd-picolo picolo"
+setuuid watchdog 5e729c61-f33f-d703-0550-ba440a71a6afda79
+define RPiMaster RPI_1Wire BUSMASTER
+setuuid RPiMaster 654a38fa-f33f-d703-f38c-a3dc2297e7b995d6
+define Zimmer1Temp RPI_1Wire 28-00000a54cd2a
+setuuid Zimmer1Temp 654a7665-f33f-d703-cfe8-494db38bfeecea44
+attr Zimmer1Temp room RPI_1Wire,Temperaturen
+define KNX_0002003 KNX 0/2/3:dpt9.001
+setuuid KNX_0002003 656641be-f33f-d703-7a08-ca62fcd333a7516a
+attr KNX_0002003 IODev KNX
+attr KNX_0002003 alias MZimmerTemp
+attr KNX_0002003 room KNX
+define KNX_0002004 KNX 0/2/4:dpt6
+setuuid KNX_0002004 6566561b-f33f-d703-ce4e-c9c35d16d0d2f43b
+attr KNX_0002004 IODev KNX
+attr KNX_0002004 room KNX
+define KNX_0002002 KNX 0/2/2:MODEL_NOT_DEFINED
+setuuid KNX_0002002 656658a8-f33f-d703-fcb2-0547e4c2c7d72cc4
+attr KNX_0002002 disable 1
+attr KNX_0002002 room KNX
+define Z1TempSetter at +*00:03:00 set KNX_0002003 g1 {(ReadingsNum("Zimmer1Temp","temperature",0))}
+setuuid Z1TempSetter 656e11f7-f33f-d703-98d3-b892c1812275b7f7
+attr Z1TempSetter room KNX